Welcome: Global East Asia Technology Co.LTD

sales@global-antenna.com 86-371-60911368

Hot Sales

  • GLS1802
  • GLS1802
  • GLS1802
GLS1802GLS1802GLS1802

GLS1802

  • P/N:GLS1802
  • Frequency:1610.0±3.0 MHz
  • Polarization:RHCP
  • Product description: GLS1802
  • INQUIRY




FOB Port: Shanghai or Shenzhen
MOQ: 1000PCS
Supply ability:10000PCS/DAY
Payment: TT,Paypal,Westen Union before shipment


Download Info: here


Items

Content

Center frequency MHz (without adhesive tape on 50*50mm square ground plane)

1610.0±3.0

real part at CF

5±15 Ω

imaginary part at CF

5±15 Ω

Polarization Model

RHCP

Impedance

50 Ω

Frequency Temperature Coefficient

20ppm/deg.℃ max

No.

Item

Test Condition

Remark

6.1

Humidity Test

The device is subjected to 90%~95% relative humidity 60℃±3℃ for 96h,then dry out at 25℃±5℃ and less than 65% relative humidity for 2h~4h. After dry out the device shall satisfy the specification in table 1.

It shall fulfill the specifications

in Table 1.

6.2

High

Temperature

Exposure

The device shall satisfy the specification in table 1 after leaving at 105℃ for 96h,provided it would be measured after 2h~4h leaving in 25℃±5 ℃ and less than 65% relative humidity.

It shall fulfill the specifications

in Table 1.

6.3

Low

Temperature

The device shall satisfy the specification in table 1 after leaving at -40℃ for 96h,provided it would be measured after 2h~4h leaving in 25℃±5 ℃ and less than 65% relative humidity.

It shall fulfill the specifications

in Table 1.

6.4

Temperature

Cycle

Subject the device to -40℃ for 30 min. followed by a high temperature of 105℃ for 30 min cycling shall be repeated 5 times. At the room temperature for 1h prior to the measurement.

It shall fulfill the specifications

in Table 1.

6.5

Vibration

Subject the device to vibration  for 2h each in xy and z axis with the amplitude of 1.5mm, the frequency shall be varied uniformly between the limits of 10Hz~55Hz.

It shall fulfill the specifications

in Table 1.

6.6

Soldering Test

Lead terminals are heated up to 350℃±10℃ for 5s±0.5 s with brand iron and then element shall be measured after being placed in natural conditions for 1 h. No visible damage and it shall fulfill the specifications in Table 1

It shall fulfill the specifications

in Table 1.

6.7

Solder ability

Lead terminals are immersed in soldering bath of 260℃~290℃ for 3s±0.5s . More than 95%  of the terminal surface of the device shall be covered with fresh solder.

The terminals shall be at least 95% covered by solder.

6.8

Terminal Pressure Strength

Force of 2kg is applied to each lead in axial direction for 10s±1 s (see drawing). No visible damage and it shall fulfill the specifications in Fig 1

Mechanical damage such as breaks shall not occur.






PREVIOUS:GL-DYS18N4 NEXT:GL1304